This is a working overview of zwitterion, written for readers who want more than a one-paragraph summary but less than a textbook.
Reviewed 2025-10-01. Anything still debated is marked as such rather than presented as settled.
Creatine is synthesized endogenously in humans, mainly in the liver, kidney, and pancreas, from the amino acids arginine, glycine, and methionine. Skeletal muscle stores much of the body's creatine, where it participates in the phosphocreatine system that buffers adenosine triphosphate during short, intense contractions. Dietary sources include meat and fish, so omnivorous diets provide additional creatine beyond endogenous production. Supplemental creatine monohydrate supplies the same molecule found in food and tissues, not a distinct drug or hormone. Research interest centers on its role in cellular energy transfer and its effects on muscle and other tissues.
Several creatine forms are sold, including monohydrate, anhydrous, hydrochloride, nitrate, citrate, and blends. Once dissolved, these forms deliver creatine, but they differ in molar mass, solubility, counterions, and water content. Creatine monohydrate has the largest body of published human data among these forms. Questions remain about whether any alternative form offers meaningful advantages in absorption, tolerability, or tissue uptake under practical conditions. The hydrate form's lower creatine content by mass is a compositional fact, not a statement about effectiveness.
Creatine monohydrate is a crystalline compound formed when one molecule of creatine associates with one molecule of water in the solid lattice. Its molecular formula is C4H11N3O3, and its molar mass is about 149.15 grams per mole. The material appears as a white, odorless powder that dissolves sparingly in water at room temperature. The monohydrate designation distinguishes it from anhydrous creatine, which lacks the bound water and has a lower molar mass. This hydrate is the most common commercial form of creatine used in nutritional and research settings.
Commercial creatine monohydrate is typically a white to off-white powder with low odor. It is commonly sold as a fine powder, micronized powder, or larger crystals, but these are physical forms of the same chemical. Purity grades vary, and products may contain small amounts of related substances such as creatinine, dicyandiamide, or moisture. The monohydrate is often selected for supplements and research because its production is well established and its behavior in water is predictable. Analytical certificates usually report assay, loss on drying, and heavy metals.
Creatine monohydrate is a crystalline compound formed from creatine and one water molecule in its solid lattice. Creatine itself is a nitrogen-containing organic acid involved in energy transfer in muscle and other tissues. The monohydrate form is the most common solid form used in research and commercial products because it is stable and easy to handle. The term "monohydrate" refers to the fixed one-to-one ratio of water to creatine in the crystal, not to moisture content. This distinction matters when comparing labels or calculating creatine content.
| Property | Value | Notes |
|---|---|---|
| Chemical formula | C4H11N3O3 | Often written C4H9N3O2·H2O |
| Molar mass | 149.15 g/mol | Anhydrous creatine is 131.13 g/mol |
| Appearance | White crystalline powder | Odorless, fine or granular |
| Water solubility | About 13 g/L at 25 °C | Low; increases with temperature |
| Common synonyms | Creatine hydrate; N-carbamimidoylsarcosine monohydrate | CAS 6020-87-7 |
Since TPD observes the mass of desorbed molecules, it shows what molecules are adsorbed on the surface. Moreover, TPD recognizes the different adsorption conditions of the same molecule from the differences between the desorption temperatures of molecules desorbing different sites at the surface, e.g. terraces vs. steps. TPD also obtains the amounts of adsorbed molecules on the surface from the intensity of the peaks of the TPD spectrum, and the total amount of adsorbed species is shown by the integral of the spectrum. To measure TPD, one needs a mass spectrometer, such as a quadrupole mass spectrometer or a time-of-flight (TOF) mass spectrometer, under ultrahigh vacuum (UHV) conditions. The amount of adsorbed molecules is measured by increasing the temperature at a heating rate of typically 2 K/s to 10 K/s. Several masses may be simultaneously measured by the mass spectrometer, and the intensity of each mass as a function of temperature is obtained as a TDS spectrum. The heating procedure is often controlled by the PID control algorithm, with the controller being either a computer or specialised equipment such as a Eurotherm. Other methods of measuring desorption are Thermal Gravimetric Analysis (TGA) or using infrared detectors, thermal conductivity detectors etc.
A biomaterial should perform its intended function within the living body without negatively affecting other bodily tissues and organs. In order to prevent unwanted organ and tissue interactions, biomaterials should be non-toxic. The toxicity of a biomaterial refers to the substances that are emitted from the biomaterial while in vivo. A biomaterial should not give off anything to its environment unless it is intended to do so. Nontoxicity means that biomaterial is: noncarcinogenic, nonpyrogenic, hypoallergenic, blood compatible, and noninflammatory. However, a biomaterial can be designed to include toxicity for an intended purpose. For example, application of toxic biomaterial is studied during in vivo and in vitro cancer immunotherapy testing. Toxic biomaterials offer an opportunity to manipulate and control cancer cells. One recent study states: "Advanced nanobiomaterials, including liposomes, polymers, and silica, play a vital role in the codelivery of drugs and immunomodulators. These nanobiomaterial-based delivery systems could effectively promote antitumor immune responses and simultaneously reduce toxic adverse effects." This is a prime example of how the biocompatibility of a biomaterial can be altered to produce any desired function.
Two-sample hypothesis tests are appropriate for comparing the two samples in which the samples are divided by the two control cases in the experiment. Z-tests are appropriate for comparing means under stringent conditions regarding normality and a known standard deviation. Student's t-tests are appropriate for comparing means under relaxed conditions when less is assumed. Welch's t-test assumes the least and is therefore the most commonly used two-sample hypothesis test in which the mean of a metric is to be optimized. While the mean of the variable to be optimized is the most common choice of estimator, others are regularly used. Fisher's exact test can be employed to compare two binomial distributions, such as a click-through rate.
In collaboration with the Academic Medical Center in Amsterdam, Inreda Diabetic B.V. has developed a closed loop system with insulin and glucagon. The initiator, Robin Koops, started to develop the device in 2004 and ran the first tests on himself. In October 2016 Inreda Diabetic B.V. got the ISO 13485 license, a first requirement to produce its artificial pancreas. The product itself is called Inreda AP, and soon made some highly successful trials. After clinical trials, it received the CE marking, noting that it complies with European regulation, in February 2020. In October 2020 the health insurance company Menzis and Inreda Diabetic then started a pilot with 100 patients insured by Menzis. These are all patients that face very serious trouble in regulating their blood glucose levels. They now use the Inreda AP instead of the traditional treatment. Another large scale trial with the Inreda AP was set up in July 2021, and should determine whether Dutch health insurance should cover the device for all their insured. A smaller improved version of the Inreda AP is scheduled for release in 2023.
An alcohol burner or spirit lamp is a piece of laboratory equipment used to produce an open flame. It can be made from brass, glass, stainless steel or aluminium. Alcohol burners are preferred for some uses over Bunsen burners for safety purposes, and in laboratories where natural gas is not available. Their flame is limited to approximately 5 centimeters (two inches) in height, with a comparatively lower temperature than the gas flame of the Bunsen burner. While they do not produce flames as hot as other types of burners, they are sufficiently hot for performing some chemistries, standard microbiology laboratory procedures, and can be used for flame sterilization of other laboratory equipment. A small alcohol burner is also preferred for camping when the need for fire is modest. It burns the alcohol vapor that rises due to the heat from the flame through the holes on the top perimeter of the container. Typical fuel is denatured alcohol, methanol, or isopropanol. A cap is used as a snuffer for extinguishing the flame.
Sources: en.wikipedia.org
In the presence of air and various cofactors and enzymes, fatty acids are converted to acetyl-CoA. The pathway is called beta-oxidation. Each cycle of beta-oxidation shortens the fatty acid chain by two carbon atoms and produces one equivalent each of acetyl-CoA, NADH, and FADH2. The acetyl-CoA is metabolized by the citric acid cycle to generate ATP, while the NADH and FADH2 are used by oxidative phosphorylation to generate ATP. Dozens of ATP equivalents are generated by the beta-oxidation of a single long acyl chain. In oxidative phosphorylation, the key control point is the reaction catalyzed by cytochrome c oxidase, which is regulated by the availability of its substrate – the reduced form of cytochrome c. The amount of reduced cytochrome c available is directly related to the amounts of other substrates: 1 2 NADH + cyt c ox + ADP + P i ⇌ 1 2 NAD + + cyt c red + ATP {\displaystyle {\frac {1}{2}}{\ce {NADH}}+{\ce {cyt}}\ {\ce {c_{ox}}}+{\ce {ADP}}+{\ce {P_{i}}}\rightleftharpoons {\frac {1}{2}}{\ce {NAD^+}}+{\ce {cyt}}\ {\ce {c_{red}}}+{\ce {ATP}}}
Professional APCs describe those APCs which are capable of delivering all 3 signals needed to activate a naive T cell (signal 1- the antigen itself, the peptide-MHC complex; signal 2 - costimulatory ligand; signal 3- cytokines to guide polarization of the T cell). Canonically, the 3 pAPC types are dendritic cells, macrophages, and B cells. They are very efficient at internalizing antigens, either by phagocytosis (e.g. macrophages), or by receptor-mediated endocytosis (B cells), processing the antigen into peptide fragments and then displaying those peptides (bound to a class II MHC molecule) on their membrane. The T cell recognizes and interacts with the antigen-class II MHC molecule complex on the membrane of the antigen-presenting cell. An additional co-stimulatory signal is then produced by the antigen-presenting cell, leading to activation of the T cell. The expression of co-stimulatory molecules and MHC class II are defining features of professional APCs. All professional APCs also express MHC class I molecules as well. The main types of professional antigen-presenting cells are dendritic cells, macrophages and B cells.
The AToFMS allows for the determination of mixing state, or distribution of chemical species, within individual particles. These mixing states are important in the determination of climate and health impact of aerosols. The schematic of a typical AToFMS is shown to the right. The overall structure of ATOF instruments is; sampling, sizing, and the mass analyzer region. The inlet system is similar to the AMS by using the same aerodynamic focusing lens, but it has smaller orifices because of its analysis of single particles. In the sizing region particle passes through the first continuous solid state laser that generates an initial pulse of scattered light. Then the particle passes through the second laser that is orthogonal to the first and produces a pulse of scattered light. The light is detected by a photomultiplier (PMT) that is matched up to each laser. Using the transit times between the two detected pulses and the fixed distance the velocity and size of each particle is calculated. Next the particles travel through to the mass analyzer region where it is ionized by a pulsed LDI laser, which is timed to hit the particle as it reaches the center of the ion extraction region. Once ionized, the positive ions are accelerated towards the positive ToF section and the negative ions are accelerated towards the negative ToF section where they are detected.
Programmed cell death in plants has a number of molecular similarities to that of animal apoptosis, but it also has differences, notable ones being the presence of a cell wall and the lack of an immune system that removes the pieces of the dead cell. Instead of an immune response, the dying cell synthesizes substances to break itself down and places them in a vacuole that ruptures as the cell dies. Additionally, plants do not contain phagocytic cells, which are essential in the process of breaking down and removing apoptotic bodies. Whether this whole process resembles animal apoptosis closely enough to warrant using the name apoptosis (as opposed to the more general programmed cell death) is unclear.
Sources: en.wikipedia.org
Annals of Clinical Biochemistry is a bimonthly peer-reviewed scientific journal covering all aspects of clinical biochemistry. The editor-in-chief is Michael J Murphy (University of Dundee). It was established 1960 and is published by SAGE Publications on behalf of The Association for Clinical Biochemistry and Laboratory Medicine. The journal is abstracted and indexed in: According to the Journal Citation Reports, its 2012 impact factor is 1.922, ranking it 12th out of 31 journals in the category "Medical Laboratory Technology". Official website
failure mode and effects analysis (FMEA) manual statistical process control (SPC) manual measurement systems analysis (MSA) manual production part approval process (PPAP) manual APQP serves as a guide in the development process and also a standard way to share results between suppliers and automotive companies. APQP specifies three phases: Development, Industrialization, and Product Launch. Through these phases, 23 main topics will be monitored. These topics must be completed before the production is started. They include the following aspects: design robustness, design testing, and specification compliance, production process design, quality inspection standards, process capability, production capacity, product packaging, product testing, and operator training plan. These activities are sometimes carried out by third-party inspection and quality control companies such as SGS, Bureau Veritas, or QCADvisor, which provide on-site inspections, audits, and testing services to support APQP compliance. APQP focuses on:
NETA is a prodrug of norethisterone in the body. Upon oral ingestion, it is rapidly converted into norethisterone by esterases during intestinal and first-pass hepatic metabolism. Hence, as a prodrug of norethisterone, NETA has essentially the same effects, acting as a potent progestogen with additional weak androgenic and estrogenic activity (the latter via its metabolite ethinylestradiol).
Closer Roberto Osuna converted his 25th consecutive save on May 24, breaking a club record. The streak had started the previous August 18, surpassing Brad Lidge (24 consecutive from June 21–September 28, 2005). Osuna's feat remained the franchise longest until Josh Hader converted 29 consecutive from April 7 to August 29, 2024. On May 28, A. J. Hinch obtained his 500th win as manager, as the Astros toppled the Chicago Cubs, 9–6. Chicago blasted five home runs, but Houston answered with five doubles—two by Jake Marisnick (8)—and two home runs by Alex Bregman (17). Bregman collected three RBI, and Michael Brantley had two hits and two RBI as Houston scored four times in the bottom of the fourth. Josh James (2–0) picked up the victory in relief while surrendering three runs over 2+1⁄3 frames. With injuries stacking up, on May 29 shortstop Carlos Correa sustained a bruised rib during a massage session. He was forced to join fellow All-Stars Springer and Jose Altuve on the injured list (IL) and expected to miss four to six weeks.
A 15-hydroxyicosatetraenoate dehydrogenase metabolizes 15-hydroxyicosatetraenoic acid (i.e. 15(S)-hydroxy-5Z,8Z,11Z,13E-eicosatetraenoic acid or 15-HETE) to its 15-keto analog, 15-oxo-ETE, using NAD+ and NADH rather than NADP+ and NADPH as its co-factors. 15-Oxo-ETE appears to have a somewhat different spectrum of activities than its precursor, 15-HETE (see 15-Hydroxyicosatetraenoic acid
Sources: en.wikipedia.org
It is the hydrated crystalline form of creatine, containing one bound water molecule per creatine unit. The compound is commonly used as a nutritional ingredient and as a research material.
Yes, endogenous synthesis occurs mainly in the liver, kidney, and pancreas. Meat and fish also contribute creatine to the diet.
Other forms contain creatine paired with different counterions or lacking water, so their mass and solubility differ. After dissolution, creatine itself is the shared active molecule.
It is a solid form of creatine that contains one water molecule per creatine molecule in the crystal lattice. The hydrate water is part of the crystal structure rather than loose moisture. The term is often used for the common crystalline powder grade.